Submittals
Next Gen Arctic Series Submittal
Rev. Feb 2021
Electrical Requirement
Power Supply
208/230V, 1 Phase,
60 HZ
Operating Voltage Range 187~253 VAC
Recommended Fuse/Breaker Size 15A
MCA 13A
Cooling Performance
Rated Cooling Capacity 9,000 BTU
Cooling Capacity Range 3,100~12,000 BTU
Rated Power input
560 W
SEER 30.0
EER 16.0
Moisture Removal 2.5 Pt./h
Heating Performance
Rated Heating Capacity 10,000 BTU
Heating Capacity Range 3,100~20,000 BTU
Rated Power Input 845 W
HSPF 15.2
Pipe Length
Minimum Pipe Length 10 ft
Maximum Pipe Length 50 ft
Maximum Pipe Height Dierence 33 ft
Flare Connections
Liquid 1/4”
Vapor 1/2”
Operating Range
Cooling With Wind Bae
14~115°F (-10~46°C)
Cooling Without Wind Bae 23~115°F (-5~46°C)
Heating -31~75°F (-35~24°C)
Job Name: __________________________________
Purchaser: __________________________________
Submitted To: _______________________________
Construction: _______________________________
Reference: __________________________________
Approval: ___________________________________
Date: ______________________________________
Submitted By: _______________________________
Unit: _______________________________________
Drawing #: __________________________________
CUS
Intertek
Accessories
9000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM
1U09EH2VHE / AW09EH2VHD
Remote Controller
Ships with Motion Sense Remote (WJ26X27153)
Wired Controller
Compatible with the Simplied (QACT17A) and
Programmable (YR-E16B) wall controllers.
Wind Bae
Uses wind bae QAWB37A
Built-in Features
• WK-B wired controller adapter
• WiFi
• Occupancy sensor
For more information visit us:
www.Haierductless.com
www.Haierductlesshelp.com
Connecting cable to indoor units must be 14/4 AWG unshielded stranded
copper. Cable must be ran continuous, without splicing.