Submittals
Next Gen Arctic Series Submittal
Rev. Feb 2021
Outdoor Unit
Compressor DC inverter Driven Rotary
Uncrated Dimension (HxWxD)
30 x 36 1/4 x 15 1/8 in
762 x 920 x 385 mm)
Crated (HxWxD)
34 x 42 3/4 x 19 1/8 in
(863 x 1085 x 487 mm)
Outdoor Sound Rating dB 52
Heat Exchanger Fin Type Blue Fin
Weight (Ship/Net) 154.3/133.4 lbs
Factory Refrigerant Charge R-410A (82.9 oz)
18000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM
1U18EH2VHE / AW18EH2VHD
1U18EH2VHD
36 1/4 (920)
30 (792)
15 1/8 (385)
AW18EH2VHD
44 3/8 (1126)
9 (230)
13 1/4 (337)
Indoor Unit
Uncrated Dimension (HxWxD)
13 1/4 x 44 3/8 x 9 in
(337 x 1126 x 230 mm)
Crated (HxWxD)
16 1/2 x 47 1/2 x 13 1/2 in
(418 x 1206 x 342 mm)
Airow CFM
(Turbo/High/Med/Low/Quiet)
636/541/436/330/259
Indoor Sound Level dB
(Turbo/High/Med/Low/Quiet)
47/41/38/35/29
Motor Rating (HP) 0.07
Heat Exchanger Fin Type Blue Fin
Weight (Ship/Net) 45.2/36.6 lbs
Floor Mounting
Dimensions
5 1/8
(130)
26
(660)
5 1/8
(130)
15 3/4
(400)
Heating Capacity Data
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum
Capacity (Btu/h)
Power Usage
(w) COP
Maximum
Capacity (Btu/h)
Power Usage
(w) COP
Maximum
Capacity (Btu/h)
Power Usage
(w) COP
-31
O
F (-35
O
C) 7,622 2,991 0.75 7,400 3,053 0.71 7,252 3,236 0.66
-22
O
F (-30
O
C) 14,420 2,511 1.68 14,000 2,563 1.60 13,720 2,716 1.48
-15
O
F (-26
O
C) 16,480 2,417 2 16,000 2,467 1.90 15,680 2,615 1.76
-4
O
F (-20
O
C) 18,900 2,256 2.45 18,000 2,375 2.22 17,100 2,494 2.01
5
O
F (-15
O
C) 21,000 2,375 2.59 20,000 2,500 2.34 19,000 2,625 2.12
17
O
F (-8
O
C) 22,050 2,204 2.93 21,000 2,320 2.65 19,950 2,436 2.40
47
O
F (8
O
C) 27,300 2,451 3.26 26,000 2,580 2.95 24,700 2,709 2.67
Capacity and power usage are measured under the assumption of indoor humidity of 46%
* Cooling Capacity under low ambient temperature below 23
O
F (-5
O
C) are tested when using wind bae on outdoor unit
Cooling Capacity Data
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Maximum
Capacity (Btu/h)
Power Usage
(w) EER
Maximum
Capacity (Btu/h)
Power Usage
(w) EER
Maximum
Capacity (Btu/h)
Power Usage
(w) EER
14
O
F (-10
O
C)* 23,376 1,810 12.92 24,392 1,743 14.00 25,408 1,676 15.16
32
O
F (0
O
C) 23,045 1,829 12.60 24,047 1,761 13.65 25,049 1,693 14.79
50
O
F (10
O
C) 22,714 1,848 12.29 23,702 1,780 13.32 24,689 1,711 14.43
65
O
F (18
O
C) 22,493 1,867 12.05 23,471 1,798 13.06 24,449 1,729 14.14
75
O
F (24
O
C) 22,273 1,886 11.81 23,241 1,816 12.80 24,210 1,746 13.86
85
O
F (29
O
C) 22,052 1,905 11.58 23,011 1,835 12.54 23,970 1,764 13.59
95
O
F (35
O
C) 21,160 2,009 10.53 22,080 1,934 11.41 23,000 1,860 12.37
105
O
F (41
O
C) 20,525 2,029 10.12 21,418 1,954 10.96 22,310 1,879 11.88
115
O
F (46
O
C) 20,102 2,049 9.81 20,976 1,973 10.63 21,850 1,897 11.52