Service Guide
Table Of Contents
23
(4) Lead the connection tubing(liquid pipe and gas pipe) through the hole into the wall, or connect piping and wiring
of indoor unit(check the number of wiring terminals of indoor and outdoor units and connect terminals with the same
number and color), and then put the connection tubing and the connecting line through from the inside wall for the
connection with outdoor unit.
When the mounting plate is rst xed
1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be xed against the wall,
then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the
plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape.
Pay attention to the following points before installation of machine:
1. Take out cushion blocks on the left and right angle beads as
shown in the following Figure.
Fitting of the Mounting Plate and Positioning of the wall Hole