9.3 Emergency Running & Test operation
Emergency Running & Test operation:
Emergency running will help air conditioner operate automatically if your remote control is missing or out of work.
Test operation is recommended when room temperature is below 60.8*(16*) but not in normal condition.
Temperature setting values and wind speed cannot be changed in the mode of emergency running. Meanwhile,
dehumidication and timing operation cannot be operated simultaneously.
It is recommended when the room temperature is below 60.8*(16*) but
not in normal condition.
Set Temp Wind Speed Working Mode
75.2°F(24°C) auto auto
It is recommended to use only when the remote control is missing or damaged.
Startup
A warning tone could be heard after turning on the Emergency Running switch,which means that the emergency
running gets started.
Air conditioner operates automatically according to the working modes blow:
Shutdown (canceling the emergency running)
All the indicator lamps on the conditioner extinguish after pressing
the emergency running switch and hearing the warning tone.
Canceling the emergency running with the remote controller A
warning tone is heard after pressing the ON/OFF button on remote
controller. The air conditioner works according to the indication of
operating state on the remote controller.
Startup
Press it for over 5 seconds till 2 warning tones are heard and then
release your finger to start the test operation. The air conditioner
is operating at high wind speed. The test operation lasts for 30
minutes before the air conditioner stops automatically.
Shutdown (canceling the test operation)
The warning tones are followed after pressing the test operation
switch.
Canceling the test operation with the remote controller
The warning tone could be heard after pressing the switch on
remote controller.
The air conditioner works according to the indication of operating
state on the remote controller.
Emergency Running
Test Operation