Owners Manual

12 49-5000255
ENGLISH
INSTALLATION INSTRUCTIONS
2. Preparation Before Installation
B. Lifting dimension of connection kit (inches)
NOTE:
When three indoor units are connected to MS3-036A; please connect indoor units according to the label A, B, and C.
When only one or two indoor units are connected to MS3-036A; please remove all the plastic caps first. Unused
connection ports of valve box need to be sealed using a brass flare cap to prevent refrigerant leakage.
See the figures above to install the lifting bolts and hoisting tools.
Use the lifting bolts with the size of M8~M10
Press insert for new settings. Press hole in anchor if set. Ensure that it can sufficiently
withstand the weight of the connection kit before installation.
1.46”
2.76”
16.81”
2.76”
4.65”
MS1-036A
13.58”
MS3-036A
13.74”
16.93”
A B C
Thick cement plate
Foundation bolt
Long nuts or turnbuckle
Lifting bolt
Connection
kit
Lifting tools
Less than 4’
Less than 4’
Note: All the parts in the
are purchased locally.