Submittals
Tempo Submittal
Rev. Feb. 2021
Cooling Performance
Rated Cooling Capacity 18,000 BTU
Cooling Capacity Range 5,000~19,000 BTU
Rated Power input 1,650 W
SEER 16.0
EER 10.0
Heating Performance
Rated Heating Capacity 19,000 BTU
Heating Capacity Range 5,400~22,000 BTU
HSPF 9.0
18,000 BTU 16 SEER Wall Mount Single-Zone Heat Pump System
1U18TE2VHA / AW18TE2VHA
CUS
Intertek
For more information visit us:
www.Haierductless.com
www.Haierductlesshelp.com
Electrical Requirement
Power Supply
208/230V, 1 Phase,
60 HZ
Operating Voltage Range 187~253 VAC
Recommended Fuse/Breaker Size 20A
MCA 17A
Connecting cable to indoor units must be 14/4 AWG unshielded stranded
copper. Cable must be ran continuous, without splicing.
Job Name: __________________________________
Purchaser: __________________________________
Submitted To: _______________________________
Construction: _______________________________
Reference: __________________________________
Approval: ___________________________________
Date: ______________________________________
Submitted By: _______________________________
Unit: _______________________________________
Drawing #: __________________________________
Accessories
Controller Model/Part Number Note
Ships with
Standard Remote Control
(WJ01X24721)
Compatible
Controllers
Simplied Wired Controller
(QACT17A)
Requires
WK-B kit
Programmable Wired Controller
(YR-E16B)
Requires
WK-B kit
WiFi Module QAWF01A
Wind Bae QAWB41A
Operating Range
Cooling with Wind Bae 0~115°F (-18~46°C)
Cooling Without Wind Bae 23~115°F (-5~46°C)
Heating -4~75°F (-20~24°C)
Pipe Length
Minimum Pipe Length 6 ft
Maximum Pipe Length 83 ft
Maximum Pipe Height Dierence 50 ft
Flare Connections
Liquid 1/4”
Vapor 1/2”