Installation Guide
Relocation Procedures 
Note: in case relocation is required, the joint of evaporator gas/liquid pipes of the indoor unit shall be cut off with 
a cutting knife. Connection is only allowed after re-flaring (the same to the outdoor unit). 
Maintenance Instructions 
Maintenance Precautions 
Precautions 
• For all the faults requiring welding the refrigeration pipelines or components inside the refrigeration system
of R32 refrigerant air conditioners, maintenance at the user’s site is never allowed.
• For  the  faults  requiring  radical  disassembly  and  bending  operation  of  the  heat  exchanger,  such  as  the
replacement of the outdoor unit chassis and integral disassembly of the condenser, inspection and maintenance at
the user’s site are never allowed.
• For  the  faults  requiring  replacement  of  the  compressor  or  parts  &  components  of  refrigeration  system,
maintenance at the user’s site is not allowed.
• For  other  faults  not  involved  in  the  refrigerant  container,  internal  refrigeration pipelines  and  refrigeration
elements, the maintenanc
e at the  user’s site is  allowed, including  the cleaning and dredging of the refrigeration
system requiring no disassembly of refrigeration elements and no welding.
• In  case  replacement  of  gas/liquid  pipes  is  required  during  maintenance, the  joint  of  evaporator  gas/liquid
pipes of the indoor unit shall be cut off with a cutting knife. Connection is only allowed after re-flaring (the same
to the outdoor unit).
Qualification Requirements of Maintenance Personnel 
1. All the operators or the maintenance personnel involved in refrigerating circuits shall be provided with the
effective certificate issued by an industry-accepted assessment institute, to ensure that they are qualified for safety
disposal of refrigerant as required in the assessment regulations.
2. The equipment can only be maintained and repaired as per the method recommended by the manufacturer.
In  case  the 
assistance  from personnel of other  disciplines  is  required,  the  assistance  shall  be  supervised  by  the
personnel with qualification certificate involved in flammable refrigerant.
7
Inspection on  system 
leakage prior to 
disassembly 
Inspection on 
operational state 
Refrigerant recovery 
by the system 
Cleaning 
of 
the indoor 
unit 
and connecting pipes with 
inert gas 
Disassembly 
Installation as required 
in 
standards 
Safety discharge 
of 
refrigerant 
Safety discharge 
of 
refrigerant 