Suction temperature sensor failure
When the The wiring of compressor is wrong or 
the connection is poor
17
16
15
Lack of refrigerant
Check if there is leakage in the unit.
m
25
Troubleshooting 
CAUTION! 
•  THIS UNIT WILL 
BE 
STARTED INSTANTLY WITHOUT "ON" OPERATION WHEN ELECTRIC POWER 
IS 
SUPPLIED. 
BE 
SURE TO EXECUTE "OFF" OPERATION BEFORE ELECTRIC POWER 
IS 
DISCONNECTED FOR SERVICING. 
•  This unit has a function 
of 
automatic restart system after recovering power stoppage. 
1. Before starting test run (for all Heat pump models) 
Confirm whether the power source breaker (main switch) 
of 
the unit has been turned 
on 
for over 12 hrs to energize the 
crankcase heater 
in 
advance 
of 
operation. 
2.Test run 
Run the unit continuously for about 30 minutes, and check the following. 
• Suction pressure at check joint 
of 
service valve for gas pipe. 
• Discharge pressure at check joint 
on 
the compressor discharge pipe. 
• Temperature difference between return air and supply air for indoor unit. 
Flash times 
of 
LED 
Trouble description 
on mainboard 
Analyze and diagnose 
Eeprom failure  Outdoor main board eeprom fail 
1PM 
failure 
1PM 
failure 
Communication error between main board and 
Communication fail over 4min 
sodu module 
SPDU Communication error 
High pressure protection  System high pressure over 4. 
Mpa 
Compressor discharging temperature protection  Compressor discharging temperature over  centigrade 
Abnormal 
of 
DC mater  Jam of DC motor 
or 
motor failure 
Abnormal 
of 
piping sensor  Piping sensor short-circuit 
or 
open-circuit 
Abnormal 
of 
outdoor ambient sensor  Outdoor ambient sensor short-circuit or open-circuit 
Abnormal 
of 
compressor discharge sensor 
Compressor discharge sensor short-circuit 
or 
open-circuit 
Communication 
error 
between  indoor and 
Communication fail over 4min 
outdoor unit 
Alarm and  stop 
if 
detect 
T  <= 
last 
for 
1 min 
after 
4-way valve reverse failure 
compressor has started for 
1 0min 
in 
heating mode, confirm 
the failure 
if 
it appears 3 times 
in 
one hour. 
Compressor jam(only for spdu)  Inner compressor is abnormal jamed 
Module PWM select circuit error  Module PWM select wrong circuit 
Compressor Li-phase over-current  The current 
of 
compressor Li-phase is too high 
Compressor V-phase over-current  The current 
of 
compressor V-phase 
is 
too high 
Compressor W-phase over-current  The current 
of 
compressor W-phase is too high 