Installation Guide
R32
R32
R32
R32
R32
R32
R32
R32
R32
17
Read Before Installation 
Items to Be Checked 
(1 
). 
Verify the type 
of 
refrigerant used by the unit to be serviced. Refrigerant Type: 
(2).  Check the symptom exhibited by the unit to be serviced. Look 
in 
this service handbook for symptoms relating to the 
refrigerant  cycle. 
(3).  Be sure to carefully read the safety precautions at the beginning 
of 
this document. 
(4 
). 
If there is a gas leak or if the remaining refrigerant is exposed to 
an 
open flame, a noxious gas hydrofluoric acid may 
form.  Keep workplace well ventilated. 
CAUTION 
• Install new pipes immediately after removing old ones to keep moisture out 
of 
the refrigerant circuit. 
• Chloride 
in 
some types 
of 
refrigerants such as R22 will cause the refrigerating machine oil to deteriorate. 
Necessary Tools and Materials 
Prepare the following tools and  materials necessary for installing and servicing the unit. 
Necessary tools for use with  (Adaptability 
of 
tools that are for use with R22 and R407C). 
1. 
To 
be used exclusively with  ( Not to be used if used with R22 
or 
R407C ) 
Tools/Materials  Use  Notes 
Gauge Manifold  Evacuating.refrigerant charging  5.09MPa on the High-pressure side. 
Charging Hose  Evacuating, refrigerant charging  Hose diameter larger than the concentional ones. 
Refrigerant Recovery Equipment  Refrigerant recovery 
Refrigerant Cylinder  Refrigerant charging  Write down the refrigerant type.  Pink 
in 
color at the top 
of 
the cylinder. 
Refrigerant Cylinder Charging Port  Refrigerant charging  Hose diameter larger than the conventional ones. 
Flare Nut  Connecting the unit to piping  Use Type-2 Flare nuts. 
2. 
Tools and  materials that may be  used with  with some restrictions 
Tools/Materials  Use  Notes 
Gas leak detector  Detection 
of 
gas leaks  The ones for HFC type refrigerant may be used. 
Vacuum Pump  Vacuum drying  May 
be 
used if a reverse flow check adaptor is attached. 
Flare Tool  Flare machining 
of 
piping  Chages have been made 
in 
the flare machining dimension.Refer to the next page. 
Refrigerant Recovery Equipment  Recovery 
of 
refrigerant  May 
be 
used if designed for use with 
3. 
Tools and  materials that are used with R22 or R407C that can also be  used with 
Tools/Materials  Use  Notes 
Vacuum Pump with a Check Valve  Vacuum drying 
Bender  Bending pipes 
Torque Wrench  Tightening flare nuts 
Only 
cj:,12.70 
(1/2") and 
cj:, 
15.88(5/8") have a larger flare machining dimension. 
Pipe Cutter  Cutting pipes 
Welder and  Nitrogen Cylinder  Welding pipes 
Refrigerant Charging Meter  Refrigerant charging 
Vacuum Gauze  Checking vacuum degree 
4. 
Tool 
and materials that must not used with 
Tools/Materials  Use  Notes 
Charging Cylinder  Refrigerant Charging  Must not be used with  -type units. 
Tools for  must be handled with special care, and keep moisture and dust from entering the cycle. 