Spec Sheet

31-5000409 Rev. 0 11
ENGLISH
SYSTEM
Model Number Outdoor 2U18MS2VHB 3U24MS2VHB 4U36MS2VHB
Operating Range Cooling °F (°C) 14~115(-10~46) 14~115(-10~46) 14~115(-10~46)
Heating °F (°C) -4~75(-20~24) -4~75(-20~24) -4~75(-20~24)
Power Supply Voltage, Cycle, Phase, V/HZ/- 208-230/60/1 208-230/60/1 208-230/60/1
Wire Size between ID and OD 14/4 AWG Stranded 14/4 AWG Stranded 14/4 AWG Stranded
Maximum Fuse Size A 25 25 30
Minimum Circuir Amp A 15 18 23
Cooling
Non-Ducted
Rated Capacity Btu/hr 17,400 22,600 34,000
Capacity Range Btu/hr 4,400-19,400 5,000-24,500 5,000-36,000
Rated Power Input W 1,650 2,250 3,770
SEER 16.0 18.0 18.0
EER 10.5 10.0 9.0
Cooling Ducted Rated Capacity Btu/hr 15,000 21,000 31,000
Capacity Range Btu/hr 4,400-19,400 5,000-23,000 5,000-34,000
Rated Power Input W 1,760 2,416 3,590
SEER 16.0 16.0 16.0
EER 8.5 8.5 8.5
Heating
Non-Ducted
Rated Heating Capacity 47°F Btu/hr 19,200 23,000 34,600
Heating Capacity Range Btu/hr 6,100-22,100 6,100-25,500 6,100-36,500
Rated Power Input W 1,570 1,700 2,650
HSPF 9.0 10.0 10.0
Rated Heating Capacity 17°F Btu/hr 13,000 15,000 22,000
Heating Ducted Rated Heating Capacity 47°F Btu/hr 18,000 22,000 33,000
Heating Capacity Range Btu/hr 6,100-22,100 6,100-25,000 6,100-35,000
Rated Power Input W
1,700 2,100 3,000
HSPF
8.5 8.5 9.0
Rated Heating Capacity 17°F Btu/hr 10,000 14,000 21,000
Outdoor Unit Compressor type DC Interver Driven Rotary
Outdoor Fan Speed RPM 300 ~ 900 300 ~ 900 300 ~ 900
Outdoor Noise Level dB 53 54 56
Dimension: Height in (mm) 27 1/16(688) 28 3/4(730) 33 1/16(840)
Dimension: Width in (mm) 31 7/8(810) 33 7/8(860) 37 5/16(948)
Dimension: Depth in (mm) 11 5/16(288) 12 1/8(308) 13 3/8(340)
Weight (Ship/Net)-lbs (kg) 102.5/95.9(46.5/43.5) 123.4/116.8(56/53) 191.8/167.5(87/76)
Connectable Indoor unit quantity 2 2 or 3 2, 3 or 4
Refrigerant Line Connections Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4
Suction O. D. in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2
Factory Charge Oz 49.5 67.0 113.0
Maximum Line Length Ft/m 100/30 200/60 230/70
Maximum Height Ft/m 50/15 50/15 50/15
Maximum Line Length for each
individual unit Ft/m
65/25 82/25 82/25