DEFAULT VALUES
The product has the following factory preset default values:
Datum:000 (WGS-84)
NMEA Enable Switch:GGA ON
GLL ON
GSA ON
GSV ON
RMC ON
VTG ON
Checksum ON
Baud Rate:4800 Baud
Elevation Mask:5 degrees
DOP Mask:DOP Select: Auto
GDOP: 20
PDOP: 15
HDOP: 8
Receiver Operating Mode:Normal Mode (without 1PPS)
Commands can be issued to the HI-204L to change the settings of the
receiver. The new settings will remain effective on next power-on as
long as the on-board rechargeable backup battery is not discharged.
After the backup battery is discharged, factory preset default settings
will be used.
APPENDIX B
DEFAULT VALUES
Datum:
NMEA Enable Switch:
Baud Rate:
Elevation Mask:
DOP Mask:
Receiver Operating Mode:
The product has the following factory preset default values:
Commands can be issued to the HI-204
III
to change the settings of
the receiver. The new settings will remain effective on next power-on
as long as the on-board rechargeable backup battery is not discharged.
After the backup battery is discharged, factory preset default settings
will be used.
000 (WGS-84)
GGA
GLL
GSA
GSV
RMC
VTG
Checksum ON
4800 Baud
5 degrees
DOP Select: Auto
GDOP: 10
PDOP: 10
HDOP: 10
Normal Mode (without 1PPS)
ON
OFF
ON
ON
ON
ON
( 1 sec. output)
( 5 sec. output)
( 5 sec. output)
( 1 sec. output)
( 1 sec. output)