Compatibility Sheet

Philips InstantFit LED T8 lamps
InstantFit LED T8 lamp with EasySmart technology
Ordering, electrical and technical data (Subject to change without notice)
Product
No. Model No. Ordering Code
Volts (Depending
on Ballast) Base CRI
Color Temp.
(K)
Pkg
Qty
LED
Lifetime
2
MOL
(In.)
Beam
Angle
46645-8 9290012811 14T8/48-3000 IF 10/1 EasySmart 120/277 G13 82 3000 10 50,000 48 160°
46646-6 9290012812 14T8/48-3500 IF 10/1 EasySmart 120/277 G13 82 3500 10 50,000 48 160°
46647-4 9290012813 14T8/48-4000 IF 10/1 EasySmart 120/277 G13 82 4000 10 50,000 48 160°
46648-2 9290012814 14T8/48-5000 IF 10/1 EasySmart 120/277 G13 82 5000 10 50,000 48 160°
Ordering Code Product Number Product Description
473504 929001390604 EasySmart IR Programming Tool 10/1
Product No. Bare Lamp Watts (W) Average System Watts (W)
3
Initial Lumens
4
Low Ballast
Factor (0.78)
Normal Ballast
Factor (0.88)
High Ballast
Factor (1.18)
Low Ballast
Factor (0.78)
Normal Ballast
Factor (0.88)
High Ballast
Factor (1.18)
Low Ballast
Factor (0.78)
Normal Ballast
Factor (0.88)
High Ballast
Factor (1.18)
46645-8 12.00 14.00 14.00 15.00 17.00 17.00 1800 2000 2000
46646-6 12.00 14.00 14.00 15.00 17.00 17.00 1800 2000 2000
46647-4 12.00 14.00 14.00 15.00 17.00 17.00 1900 2100 2100
46648-2 12.00 14.00 14.00 15.00 17.00 17.00 1900 2100 2100
Ballast technical data (Subject to change without notice)
Accessories
© 2017 Philips Lighting Holding B.V. All rights
reserved. Philips reserves the right to make changes in
specications and/or to discontinue any product at any time
without notice or obligation and will not be liable for any
consequences resulting from the use of this publication.
PLt-1309BN 03/17 philips.com/lighting
Philips Lighting North America Corporation
200 Franklin Square Drive, Somerset, NJ 08873
Tel. 855-486-2216
Philips Lighting Canada Ltd.
281 Hillmount Rd, Markham, ON, Canada L6C 2S3
Tel. 800-668-9008
FF0002
DQD 507 Rev. 2012-05-22 Page 1
Certificate of Compliance
Certificate: 2662008 Master Contract: 155397
Project: 2662008 Date Issued: September 27, 2013
Issued to: Philips Lighting Company, A Div. of
200 Franklin Square Dr.
Somerset, NJ 08873
USA
Attention: J. Cyre
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with adjacent
indicator 'US' for US only or without either indicator for Canada only
Issued by:
Robin Huang
PRODUCTS
CLASS 3426 36 - LUMINAIRES- Luminaire Fittings LED Tubular Lamp Retrofit Kits
LED tubular lamps as direct replacements for 25W/48T8/HF, 28W/48T8/HF, 30W/48T8/HF, 32W/48T8/RS;
F32T8, 25W; F32T8, 28W; F32T8, 30W; F32T8, 32W fluorescent lamp type, for dry or damp location use,
Models 9290002840, 9290002841, 9290002842, 9290002862.
The Ballast models that the LED Tubular Lamp can be used with are:
Philips Models: GOPA-2P32-SC, GOPA-4P32-SC, GOPA-2P32-LW-SC, GOPA-4P32-LW-SC, IOPA-2P32-N,
IOPA-4P32-N, IOPA-2P32-LW-N, IOPA-4P32-LW-N, IOP-2P32-N, IOP-4P32-N, IOP-2P32-LW-N, IOP-4P32-
LW-N, ICN-2P32-N, ICN-4P32-N
ULT Models: B232I347HP-A, B432I347HP
GE Models: GE232MAX347-N, GE432MAX347-N
UltraSave Models: UT232347, UT432347
* Please refer to www.philips.com/easysmart for instant start ballasts details and the latest compatibility for EasySmart lamps.
For more information on Philips’ limited warranty please visit www.philips.com/warranties.
Brand
Model ID/
Order Code Product Description
Leviton DLDNK-01W Intellect Decora Lumina RF 1-Button multi-function BLE keypad with room controller and LED feedback functionality, 120-277VAC, 50/60Hz, White
Leviton DLDNK-02W Intellect Decora Lumina RF 2-Button multi-function BLE keypad with room controller and LED feedback functionality, 120-277VAC, 50/60Hz, White
Leviton DLDNK-04W Intellect Decora Lumina RF 4-Button multi-function BLE keypad with room controller and LED feedback functionality, 120-277VAC, 50/60Hz, White
Leviton DLDNK-08W Intellect Decora Lumina RF 8-Button multi-function BLE keypad with room controller and LED feedback functionality, 120-277VAC, 50/60Hz, White
Leviton ZSC04-IxW Lumina RF PIR Occupancy Sensor, 450 sq ft
Leviton ZSC15-IxW Lumina RF PIR Occupancy Sensor, 1,500 sq ft
Leviton LURPC-00W Lumina RF Wireless Photocell
Leviton FREE Neuron App
Control compatibility
Philips EasySmart LED tubes now work with:
1. Savings based on comparison to F32T8 electronic instant
start systems. Savings based on operating InstantFit T8 LED
with EasySmart technology with advanced controls such as
occupancy sensing and/or dimming.
2. LED lifetime means the length of time (in hours) until half
of the LED light sources maintain at least 70% of their initial
lumen output (B50, L70).
Testing with a ballast whose ballast factor is 0.88.
3. Measured data provided as a reference. System power may
vary depending on ballast manufacturer and ballast age.
Please refer to philips.com/EasySmart for the latest ballast
compatibility guide.
4. Photometric testing consistent with IES LM-79.
This lamp is DLC 4.0 qualied.