Datasheet
–30–
EI 48
Printed circuit-board transformers Output Capacity: 7.0 VA – 15.0 VA
BV EI 481 1325 10.0 1 230 1 – 6 1 x 6 1667 8 – 11 1 x 7.6
BV EI 481 1305 10.0 1 230 1 – 6 2 x 6 833 7 – 8/11 – 12 2 x 7.6
BV EI 481 1312 10.0 1 230 1 – 6 1 x 7.5 1333 8 – 11 1 x 9.8
BV EI 481 1326 10.0 1 230 1 – 6 2 x 7.5 667 7 – 8/11 – 12 2 x 9.8
BV EI 481 1291 10.0 1 230 1 – 6 1 x 9 1111 8 – 11 1 x 11.5
BV EI 481 1271 10.0 1 230 1 – 6 2 x 9 556 7 – 8/11 – 12 2 x 11.5
BV EI 481 1295 10.0 1 230 1 – 6 1 x 12 833 8 – 11 1 x 15.5
BV EI 481 1327 10.0 1 230 1 – 6 2 x 12 417 7 – 8/11 – 12 2 x 15.3
BV EI 481 1323 10.0 1 230 1 – 6 1 x 15 667 8 – 11 1 x 18.6
BV EI 481 1324 10.0 1 230 1 – 6 2 x 15 333 7 – 8/11 – 12 2 x 18.6
BV EI 481 1307 10.0 1 230 1 – 6 1 x 18 556 8 – 11 1 x 22.3
BV EI 481 1328 10.0 1 230 1 – 6 2 x 18 278 7 – 8/11 – 12 2 x 22.3
BV EI 481 1329 10.0 1 230 1 – 6 1 x 24 416 8 – 11 1 x 28.7
Total Frame Primary Connecting Secondary Current Connecting No-load
Order No. output VA Size voltage V pins prim. voltage V sec. mA pins sec. voltage V
Dimensions in drawings:
– without tolerances ± 0.3 mm
– Soldering post 1.1 x 0.5
– Round pin Ø 0.8
Individual EI 48 transformer version
EI 48 transformers, custom-made versions.
Parallel to the cataloged EI 48 series transformers, HAHN
also produces other variants, e.g. with integrated thermo fuse
or thermo switch, other housing-, fixing- and connective options
as well as non-encapsulated transformers.
27.5
42.2±0.5
50.2±0.5
h1
6
1
h2
7
12
Type ‘0’ cast housing
without fixing straps
43
51
3.5
5
6
10
30.2
75±0.5
62
6.7
9.1
38.6
12
Type ‘SV’ for
upright mounting
42.2±0.5
40.0±0.5
h1
h2
2.3±0.8
50.2±0.5
7
12
6
1
7. 5 ±0.8
32
ø2.4
mind. 6.7
Type ‘0’ cast housing
with fixing band
View looking onto pins
View looking onto pins
View looking onto pins
EI 48/16,8
as well as for transformer version EI 48/20,5
Type „0“