Datasheet

–26–
EI 42
Printed circuit-board transformers Output Capacity: 6.0 VA
Capacity up to 10.0 VA
Non short-circuit-proof at temperature class ta 70 °C/B
Standard type with ‘K’ cast housing
Test certifications to ENEC 10-, VDE- and UL-regulations*
with VDE certificate for glow wire test in accordance to
standard EN 60335-1:2005
Excellent temperature fluctuation resistance properties
High electrical safety and long service-life features
High voltage resistance
Self-extinguishing cast housing and sealing material
Certified item quality tested
Primary protection by means of transformer heat coils to
IEC 127 standards or secondarily with PTC resistances.
25
36.8
55
h1
h2
63.3±0.4
43.8
6
7
9
10
C
D
5
4
2
1
B
A
3
8
5
5
2.5
ø 4.2±0.2
BV EI 422 1218 6.0 2 230 1 5 1 x 6 1000 7 9 1 x 8.7
BV EI 422 1219 6.0 2 230 1 5 2 x 6 500 6 7/9 10 2 x 8.7
BV EI 422 1220 6.0 2 230 1 5 1 x 7.5 800 7 9 1 x 10.9
BV EI 422 1221 6.0 2 230 1 5 2 x 7.5 400 6 7/9 10 2 x 10.9
BV EI 422 1222 6.0 2 230 1 5 1 x 9 667 7 9 1 x 13.0
BV EI 422 1223 6.0 2 230 1 5 2 x 9 334 6 7/9 10 2 x 13.0
BV EI 422 1224 6.0 2 230 1 5 1 x 12 500 7 9 1 x 16.7
BV EI 422 1225 6.0 2 230 1 5 2 x 12 250 6 7/9 10 2 x 16.7
BV EI 422 1226 6.0 2 230 1 5 1 x 15 400 7 9 1 x 20.2
BV EI 422 1227 6.0 2 230 1 5 2 x 15 200 6 7/9 10 2 x 20.6
BV EI 422 1228 6.0 2 230 1 5 1 x 18 334 7 9 1 x 24.6
BV EI 422 1229 6.0 2 230 1 5 2 x 18 167 6 7/9 10 2 x 24.6
BV EI 422 1230 6.0 2 230 1 5 1 x 24 250 7 9 1 x 30.8
Total Frame Primary Connecting Secondary Current Connecting No-load
Order No. output VA Size voltage V pins prim. voltage V sec. mA pins sec. voltage V
BV EI 422 .... / 14.8 mm 6.0 VA 26.4 mm 32.3 mm 0.200 kg 40/50 pieces*
Frame size/Core height Output ta 70 °C/B h1 (mm) h2 (mm) Weight Packaging unit
Dimensions without tolerances ± 0.3 mm,
Rights to make alterations and improvements hereby reserved
View looking onto pins
Type ‘K’ cast housing with 2 fixing straps
Soldering pin 0.6 x 0.8
Safety transformer
* it depends on kind of cast housing
* UL on request