Product Manual
  HCH HAGL Ö F HEIG H T   COM P ASS MANUAL E N G LISH   2013-0 8 -21 REV  1 .1 JN/GH 
  ©HAGL Ö F SWEDE N   A B    
’CAL’ (CALIBRATION) 
The compass needs to be calibrated at each battery change, also if the same battery is removed and used again 
or if the battery is somehow dispositioned. 
The calibration is made in the CAL menu. Press four (4) times to activate the function. Rotate the HCH instrument 
during 10-20 seconds at least 1-2 rotations, preferably on a plane surface free from magnetic objects. Another 
option is for the operator to rotate while holding and aiming with the instrument, and this method is 
recommended if wearing metal frame glasses. 
Finish the calibration after at least 1-2 spins by pressing the button. Important! Hold the HCH instrument plane 
both while measuring and calibrating! The built-in compass will show incorrect values if tilting the instrument. If 
the instrument is tilted during calibration, a message will be displayed urging you to correct the position, see 
section Compass, this manual. During calibration, the instrument shows how long time has passed since the 
calibration started (maximum timed 20 seconds)
. 
NOTE! Always test the compass function in at least four (4) 
directions after calibration! 
TECHNICAL DATA 
Size:    20x63x44mm/0,8x2,5x1,7” 
Weight:    50g/1,8oz incl battery 
Battery:    1xAA (LR6) 
Battery warning:  Yes 
Display:    LCD 
Backlit display:    Yes 
Summer:    Yes 
Consumption:    15mW 
Distance:    0-999m/ft (manual feed) 
Height:    0-999m/ft 
Resolution height:  0,1m/ft<100m/ft; 1m/ft>100m/ft 
Angle:    %/deg, -55deg…+85deg 
Accuracy angle:  +-0.2deg 
Resolution angle:  0.1deg 
DECLARATION OF CONFORMITY 
According to the EMC Directive with amendment 92/31/EEC, Low Voltage Directive 73/23/EEC and CE Marking Directive 93/68/EEC. Type of 
equipment Clinometer. Brand name or trade mark Haglöf. Manufacturer’s name, address, telephone & fax no: Haglöf Sweden AB, 
Klockargatan 8, SE-882 21 Långsele, Sweden. Tel: +46 620-25585, Fax: +46 620-20581, info@haglofsweden.com; www.haglofsweden.com 
The following standards and/or technical specifications, which comply with good engineering practice in safety matters in force within the 
EEA, have been applied: Test report/ technical construction file/normative document. Ref.no 03087/Issued by Haglöf Sweden AB.Standards 
EMC Emission EN61000-6-3: 2001, EN 55022 Class B. EMC Immunity EN61000-6-2: 2001, EN 6100-4-2, -3. The HEC Product was CE marked 
2003. As manufacturer established within EEA, we declare under our sole responsibility that the equipment follows the provisions of the 
Directives stated above. 