Product Manual

HCC Operating Guide English 2013-08-21, rev 1.1/JN/GH
Haglöf Sweden AB
free from magnetic objects. You can also, while holding and aiming with the instrument, turn around in a full
circle, 1 – 2 times/turns. This method is preferred if the operator is wearing metal framed glasses.
Leave (terminate) the calibration function after having rotated at least 1-2 times/turns, with a short press on the
button. Always remember to maintain the HCC instrument steady and flat while calibrating. If not, the built-.in
compass will show incorrect values.
While calibrating, the instrument will display the time that has passed since initiating the calibration operation
(max. time 20 sec’s)
.
NOTE! Always test the compass function in at least four (4) directions after calibration!
TECHNICAL SPECIFICATION HCC CLINOMETER COMPASS
Vertical angle -55.0 to 85 degrees
Resolution 0.1 degrees
Accuracy 0.2 degrees
Horizontal angle 0 to 359 degrees (0degrees=North)
Resolution 1 degree
Accuracy 2.5 degrees
Battery 1.5V AA
DECLARATION OF CONFORMITY
According to the EMC Directive with amendment 92/31/EEC, Low Voltage Directive 73/23/EEC and CE Marking Directive 93/68/EEC. Type of
equipment Clinometer. Brand name or trade mark Haglöf
Manufacturer’s name, address, telephone & fax no
Haglöf Sweden AB, Klockargatan 8, SE-882 21 Långsele, Sweden
Tel: +46 620-25585, Fax: +46 620-20581, info@haglofsweden.com; www.haglofsweden.com
The following standards and/or technical specifications, which comply with good engineering practice in safety matters in force within the
EEA, have been applied:
Test report/ technical construction file/normative document
Ref.no 03087/Issued by Haglöf Sweden AB.Standards EMC Emission EN61000-6-3: 2001, EN 55022 Class B
EMC Immunity EN61000-6-2: 2001, EN 6100-4-2, -3. The HEC Product was CE marked 2003
As manufacturer established within EEA, we declare under our sole responsibility that the equipment follows the provisions of the Directives
stated above.