Product Manual

HCC Operating Guide English 2013-08-21, rev 1.1/JN/GH
Haglöf Sweden AB
HOW TO USE
Both eyes should be used and kept open when working with the HCC. Use one
eye to read from the display and as guidance when aiming. The other eye is
kept open and used to sight the target. This may feel awkward in the
beginning, but is usually no problem after only a few minutes of practice.
FUNCTIONS
Choose function by pressing the button the required number of times according to the diagram below:
START THE HCC INSTRUMENT
Press the button one (1) time. The compass aim is displayed. Use the two horizontal lines in the display as your
aim.
Attempt to hold the instrument horizontally when measuring. The HCC will compensate the compass angle if
tilting to any direction up to +-10 degrees; however, the steadier the instrument is held, the better the function.
The measuring operation is terminated with a short press on the button.
NOTE! If you wish to proceed to measure a vertical angle after having stated the compass aim, terminate the
measuring operation with one (1) long press on the button. The Vertical angle is displayed, see menu Ang.
THE BATTERY
The HCC instrument uses one (1) standard AA (LR6) battery. A warning will appear in the display when the power
goes below 1.0V. A text message appears as (BAt) during a short time when starting the instrument.
1time C º Compass (0..359degrees)
2times Ang Angle measuring (-55.0..+85.0)
3times SET Settings of local deviations
4times CAL Calibration of compass
Ang
C º
CAL
SET