Operation Manual
6
Before using the unit
Please read through the instructions
carefully before using the unit and note
carefully the safety advises. Store the
manual safe and handy.
Scope of application
The equipment can be set up in a cabi-
net or can be used as a portable unit in
a carry case. It is suitable for the follow-
ing scopes:
• Footcare: Milling, trimming and polish-
ing. Attention: In fields of footcare
ones have to work with spray.
• Dental technique/ -laboratory:
Milling-, trimming and polishing work
at plaster casts and models (Do not
use this unit directly at the patient.)
•
Manicures: smoothing, trimming and
polishing.
Location of installing
The installation of the workroom must
correspond to the governing regula-
tions. Set up the appliance so that the
ventilation slits are not covered and the
exhaust air can escape well. Now con-
nect the power-supply plug to the elec-
tricity.
Fill in the spray liquid
Reduce the speed of the handpiece
with regulator (3) on minimum. Pull out
the spray tank at the grip. Hold on to the
tank cover with one hand and turn the
container of the tank off.
Now fill it with distilled water and anti
germ liquid (e.g. AQUA HY item no.
8555).
Do not exceed the maximum level
when filling the tank.
While screwing back the cover on the
tank, make sure that is closed correct.
Otherwise there will no pressure be
build up.
Put the tank back in the housing.
Turn on the unit on the main switch
(located on the back of the unit)
.
Attention: Never us tap water. (Dan-
ger of calcification). Also do not use
explosive or combustible liquids e.g.
alcohol.
Note: The filter in the tank (item no.
3479) should be fully under pressure,
otherwise no water will be sucked in.
11
Maintenance and care
Cleaning the chuck
Because of the washer, very little
dirt might enter the handpiece. In
the curse of the time, dirt can ap-
pear and might interrupt the perfor-
mance of the handpiece. Therefore
clean the chuck monthly.
Dismount the chuck
Unscrew the top of the handpiece
while using the tongs key:
Clean the inside and the top of the
handpiece now with a dry brush.
Push the black knob forward to
open the chuck.
Set the first key (see picture below) on
the axle and hold it tight. Screw out the
chuck with the second key, which has
the forefront
.
The assembly of the clamping device
takes place in reverse order. Make sure
that the clamping device is opened
when assembling it.
Cleaning the chuck
Soak the chuck in white spirit or in a
special fluid for cleaning tools. Clean
the slots of the chuck and the drilling
with a brush or a scrubber.
Rinse off the chuck well and let it dry.
Place a small drop of oil on your thumb
and pointer. Rub both fingers until you
find very little of oil on your fingers.
Now take the chuck and put it between
these two fingers and turn it around.
There should only be a very slight film
of oil on the chuck. It counts: Less is
more than too much
.