Manual Auroria Art. No. 0976 FB 04-266 Rev. 3 Foreword Date: 06.06.
Foreword Safety instructions Cleaning & Disinfection 4/5 6 Getting to know the unit 7 Before the use 8/9 Use Operation Working positioning Suction Changing filter bag Changing control unit filter Clamping the bur/ tool Setting up the speed Memory keys M1-M3 Button on the handpiece Foot switch LCD Display Messages 10 11/12 13 13 13 14 14 14 14 15 15 16 Maintenance & Care Cleaning the chuck Maintance overview Handling instructions 17 18 18/19 Troubleshooting 20 Technical data Declaration of confor
Foreword The Auroria foot care unit was produced according to strict quality criteria and uses the latest technology in its design. The images in this manual may vary slightly from the product you have bought as we are constantly developing our products. This user manual includes a detailed description and explanation of how to use the Auroria unit. If you have any questions or suggestions you can contact us by telephone or email. This user manual belongs with the Auroria unit. Keep it somewhere safe.
Safety Instructions Children should be supervised not to play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. The installation of the working area has to correspond to the relevant regulations. Set up the unit in such a way, that the air slits are not blocked and the extracted air can escape well. To avoid the risk of electrocution only connect the device to the mains power supply.
Safety Instructions Only when pulling the mains cable, you can ensure that the device will be completely disconnected from mains. Check the mains cable regularly for damages and in case of such, have it be changed or repaired by an authorized service center. Prevent your hair from wrapping itself around moving parts. If applicable, wear a hair net. When working with materials, which might create dust or moisture, use a drilling unit with suction or spray tech-nique. Wear a nose and mouth protec-tion.
Safety Instructions To ensure that the bur/ tool sits firmly in the chuck, do not work with tools which: • have an oily shaft • are worn • are bent Before using the equipment, assure that: the tool can be pushed far enough into the chuck (Test this with a dipstick and clean if necessary) the inserted tool sits properly in the chuck and will not cant/jam while clamping it the tool is approved for using it at the max speed (see manufacturer´s instructions), or only use the speed required by the instru
Safety Instructions The light on the handpiece is for lighting the area being treated. Do not look directly into the light. Never use the suction to vacuum any liquids (or air/water fog which contains particles of liquids). When the device is brought out of standby mode it will run with the rotation speed and suction power used last. Take care to not start the mill at an overly high rotation speed. Select the required rotation speed before changing the milling tool. Always follow the operating instructions.
Cleaning and disinfection Cleaning and disinfection The device is designed to be compatible with rotating instruments which do not penetrate the skin or mucosal or inadvertently may still cause injuries. For this application please adhere to the cleaning and disinfection instructions provided below. After every treatment please carry out the following steps: Remove the rotating tool (e.g. bur, capper, etc.) first. Then handle the tool according to the instructions of it`s manufacturer.
Getting to know the unit 1 2 3 4 5 6 Gerät kennen lernen 11 12 13 7 8 9 14 1 Power switch (at the side of the unit) 2 Reduce speed 3 Increase speed 4 Change direction of speed 5 Display for speed [rpm] 6 Display for suction level, time, change of the filter bag, etc.
Before the use Please read through the instructions carefully before using the unit and carefully note the safety advice. Always keep this manual accessible to any users of the drill. Operation The working area must conform to the conditions described. Set up the unit in such a way, that the air slits are not blocked and the extracted air can escape well. To guarantee unhindered air flow there must a gap of at least 12cm to the right of the device.
Before the use Should the handpiece be twisted by the hose you can adjust that at the control unit. . Check that the filter bag and dust filter are correctly fitted. (See page 13) Ensure that the tool is fixed (See page 14). On the left side of the device you will find the main power switch. Press this switch to turn the unit on. To use the handpiece and suction function press the button (14) on the front of the unit. The word "Language?" will appear on the display.
Use custom settings simply press M1. Other values can be saved using buttons M2 and M3. Operation In the following section the order in which you should use the device is described. Additionally the individual steps will be explained in detail. Read the complete manual before use. After choosing a rotation speed and suction power you can start working. If you want to take a break or finish the job press the standby button (14). The handpiece motor and suction will turn off.
Use Work positioning The following images are examples of how to work on various parts of the foot. Always make sure that the foot is firmly gripped and that you can work freely and without strain.
Use 14
Use Suction Pull out the lid of the dust chamber and remove the old filter. Switch on the suction with button (8). The suction output can be regulated in 5 levels. You will see the selected level in the display. Level 0 would mean that the suction is turned off. Hold the filter in the middle to prevend it from bending and sliding off (see picture below). Therefore you avoid it from coming off again. In case the suction motor overheats, the unit will switch off automatically.
Use Clamping the tool/ bur Memory button M1-M3 The handpiece is equipped with a chuck, which can hold all burs with a diameter of 2.35 mm (this is the diameter usually used for tools in podiatry). To open the chuck, push the knob forward with your thumb and leave it there. Now insert the tool as far as possible. Pull back the knob and the tool will be firmly clamped Frequently used speed or suction levels can be saved. Therefore three memory buttons are available.
Use By pressing the button, you will access the selective list for settings of the device. With the buttons <> and <> you can go through the list and select a setting by pressing . With you can stop a function to return to the main menu. Footswitch (Art. No. 0970) Operation of the footswitch: Only use the original hadewe foot switch, to avoid any damages. Insert the plug of the foot switch into the socket with the symbol .
Use on> or >light off< Press . Messages Check the filter bag see page 8 Display date of Maintenance Select from the list Approve with the button . The date of the last service will appear. If you send in the device for maintenance, hadewe or an approved service agent will update the date of service for you. Handpiece check No handpiece is connected or the handpiece is faulty. Maintenance recommended - After longer operation of the unit (approx.
Maintenance & Care Set the screw spanner (wrench) on the axle and hold it tight. Now use the front of the second spanner to unscrew the chuck. Cleaning the chuck Because of the additional protection washer (see right), not much dirt is usually entering the handpiece. In the process of time, some dirt might collect itself within the handpiece, and might affect its functions. Therefore the chuck has to be cleaned monthly.
Maintenance & Care Maintenance overview What has to be done? Cleaning the chuck Changing the filter Changing filter 3752 Maintenance by repair workshop (Changing worn parts; checking motor brushes, housing; Cleaning; check leakage current) How often? Done by whom? Monthly by user Each 50 hours of operation by user (check after each 10 hours) Each 200 hours of operation by user Each 500 hours of operation by repair workshop 20
Handling instructions Handling instructions Always make sure that you do not let the handpiece fall down or exposes it to any shocks. The ballbearings and the motor could be damaged by this. Never put the handpiece into any kind of liquid, and never oil or grease the handpiece. Clean its surface with a damped cloth. Pay attention, that no moisture or liquid enters the handpiece. Never use spray disinfection. Only work with tools, which are flawless.
Handling instructions Always working with maximum speed might have a similar effect. Please make sure that the speed setting you use is according to the work you are doing and the instruments you are working with.
Troubleshooting Handpiece vibrates, is very noisy and/ or becomes warm in the front part Use of bent burs/ tools Use a different bur/ tool to test this. The bur/tool itself can be tested with the hadewe Bur Shaft Tester (Art. No. (4990) to see if it is bent). Unit does not work at all. Check, if the main switch of the unit is turned on at the side of the unit.
Technical Details 0976 Auroria 0976 US Auroria 0976 UK Auroria Declaration of conformity Total weight: 2,7 kg Dimension: W273xH142xD186mm Input: 110V-230V, AC voltage 50Hz power consumption : 1A Fuse primary: F1: 3,15A time delayed safety fuse F3: 315 mA time delayed safety fuse Fuse Sec.: Thermal fuse Protection class II Accuracy of speed display: ±10% Handpiece: Type B applied part Diameter: 19-25 mm Length: 144mm Speed: 6.000 - 40.
Technical Details Accessories Art. No. 5179 3752 0970 Disposal of dust filter and coarse dust filter The filter bag and the coarse dust filter are considered low contaminated waste. Dispose those in intransparent, liquid- tight, resistant plastics sacks and to not dispose them compressed in the regular household garbage. Micro filter filter Foot switch The clamping system is designed for rotating instruments, which have a shaft of 2,35mm in accordance with ISO EN ISO 179-1.
Technical Details Symbol Caution! Important Note! Follow instructions for use Temperature limit (indicates the lower and upper temperature limit) Air pressure: range permissible Air humidity: range permissible Keep dry ON/ OFF button (standby) (no disconnection from power supply) main Enter menue / Confirm with OK C Go back in menue / Cancel Change direction Suction M1, M2, M3 Memory button 1 for speed/ suction output Rotation Alternating current Direct current Safety fuse Type B applied part S
hadewe GmbH Grambartstraße 10 30165 Hannover Germany info@hadewe.de www.hadewe.