Installation Instructions
Table Of Contents
5
The following table shows the base module state corresponding to the
LED Status Indication.
HTM-01 Base Module LED Status Indication
LED Status Indication State Description
Flashing
Green
Pairing
Base module is seeking to pair with
the thermostat.
Green
Paired
Base module is paired with the thermostat.
Red
Not
Paired
Base module is not paired with a
thermostat.
2 Red
Flashes then
Pause
Alarm
Base module indicating an alarm (Water
Leak, Smoke or CO2) accompanied by
descriptive text on the thermostat display.
Flashing
Red
Identify
Mode
Base module is in identify mode initiated by
the thermostat or web application.
Alternating
Green/Red
Factory
Reset
Hold the PAIR button for 10 seconds and
it begins to ash. Release and press again
briey to reset.
x y
Flashing
x times
Green then
y times Red
Firmware
Version
Indicates version x.y (eg. 2 green then 7
green = version 2.7.) Press and release PAIR
button within 10 seconds of power up.
n
Flash Red
n times
Base
Module
Number
Indicates base module number (1-8). Press
and release PAIR button more than 10 sec-
onds after power up.
2
LCD Display – See preceding pages for detailed descriptions of the
display icons.
– Increase or Decrease the target temperature set point.
Changing the target set point:
• Press the or button while in Auto, Heat or Cool Modes.
• If a schedule is programmed, “Override” is displayed below the
time indicating that the current target setpoint will be maintained
until the:
- Next schedule period
- Set point is changed to the scheduled value
- Mode button is held for 3 seconds, displaying “Schedule”,
“Perm. Override”
Mode – Cycle through Operation modes:
Fan – Cycle through desired Fan Speeds.
Manual Reset – Reboots the thermostat system only.
To save energy, the display will turn o after a period of inactivity.
Before making changes, press any button to activate the display,
illuminating the screen.