Full Product Manual

8
Connecting Induction Coil
1. Upon compleon of installing the inducon coil, the two wires leading from the inducon coil must be
connected to the control module.
2. You will need to strip approximately .5” of the wire insulaon from each wire.
3. There are two illuminated holes in the boom of the control module to receive the stripped wire ends.
4. To insert the coil wires into the control module there are two illuminated push buons located on the
front of the control module. Press down on the buons one at a me to insert each of the wires into the
control module.
5. Once the buons are released with the wire inserted this will lock the wire into the receptacle. Give the
wire a gentle tug to make sure wires are connected properly.
6. When roung inducon coil leads back to the control module make sure they are not twisted together or
touching each other as much as possible.
7. Make sure the two wires coming from the inducon coil are no longer than 10’ in length. These lines can
be cut shorter to desired length needed.
Features and Notifications
Example of wire with
the insulaon removed
The Elite Max i comes equipped with four color illuminaon and sound nocaons.
1. The buons on the front and wire receptacle holes on the boom of the control module will illuminate
a white light to aid with the installaon of the coil wires.
2. The logo halo will stay solid red unl a coil is detected. Once the coil is detected the logo halo will go to
solid green.
3. The solid green logo halo illuminaon will turn blue to nofy that the Elite Max i is funconing properly.
At this point the buon and coil hole illuminaon will turn o.
4. If in the event the logo halo illuminaon goes to red there is an power issue to the control module.
5. The Elite Max i is equipped with an oponal water leak detecon module.
6. In the event the water leak detecon module detects a leak an audible buzzer will sound and the logo
halo will blink red unl the water leak is reced.
Illuminated buons
and holes for wire
inseron
Solid red logo illuminaon indicates
an power issue or no coil detected,
blinking red indicates water leak
When the coil is connected
and unit is funconing proper-
ly, logo illuminaon will go