Full Product Manual
6
Installing the induction coil (continued)
9. Installing the inducon coil on copper pipe will need a double layer coil. Wrap the rst layer coil as men-
oned on the previous page.
10. When nished wrapping the rst layer and securing to the pipe with a cable e, then another layer of
wrapping must be applied on top of the rst layer of wrappings with the remaining wire.
11. The second layer of wrappings must be wrapped with the same rotaon as the rst layer of wrappings (if
the rst layer is clockwise then the second layer must be clockwise also or if the rst layer is counter clock-
wise then the second layer must be counter clockwise also).
12. When the second layer is complete secure the wire down to the pipe with a cable e (both wire leads will
exit on the same end of the inducon coil).
Note: Keep inducon coil far away as possible from elbows,
tees and couplings and never wrap coil on top of any ng.
Double layer coil wrap
Coil Chart for PVC, CPVC and PEX
NPS Pipe size Layers
Approx. Coil
Length
1/2” Double 4.5”
3/4” Single 8”
1” Single 7”
1 1/4” Single 6”
1 1/2” Single 5.5”
Note: Always
use specied
length and lay-
ers of wraps for
your pipe size.