Full Product Manual

6
Installing the induction coil (continued)
9. Installing the inducon coil on copper pipe will need a double layer coil. Wrap the rst layer coil as men-
oned on the previous page.
10. When nished wrapping the rst layer and securing to the pipe with a cable e, then another layer of
wrapping must be applied on top of the rst layer of wrappings with the remaining wire.
11. The second layer of wrappings must be wrapped with the same rotaon as the rst layer of wrappings (if
the rst layer is clockwise then the second layer must be clockwise also or if the rst layer is counter clock-
wise then the second layer must be counter clockwise also).
12. When the second layer is complete secure the wire down to the pipe with a cable e (both wire leads will
exit on the same end of the inducon coil).
Note: Keep inducon coil far away as possible from elbows,
tees and couplings and never wrap coil on top of any ng.
Double layer coil wrap
Coil Chart for PVC, CPVC and PEX
NPS Pipe size Layers
Approx. Coil
Length
1/2” Double 4.5”
3/4” Single 8”
1” Single 7”
1 1/4” Single 6”
1 1/2” Single 5.5”
Note: Always
use specied
length and lay-
ers of wraps for
your pipe size.