Full Product Manual
5
Mounting the control module
The control module can be mounted on any type of wall or surface with supplied mounng hardware. Sup-
plied hole template can be used to mark screw spacing. There are two mounng holes located on the back of
the control module.
Mounng holes
with 3”(76.2mm)
center to center
spacing
Installing the induction coil
1. Once the ideal locaon is determined for the inducon coil on the main
incoming cold-water line, then the coil must be wrapped around the out-
side of the pipe. You will need approximately 12” of straight pipe to apply
the inducon coil to.
2. There are two styles of coils applicable, a single layer coil wrapping and
a double layer coil wrapping.
3. When applying the single layer or double layer style coil determine how
long of coiling and layers needed for your size and material pipe (refer to
coil wrap chart on pages 6&7)
4. To begin the coil wrapping, mark the length of the coil needed for your
pipe size and type. Then measure out between 1’and 15’ of wire for the
rst lead to the control module (the lead wires from the coil to the control
module can be no longer than 15’ maximum but can be cut shorter to de-
sired length)
5. The rst lead must be secured to the pipe with the supplied cable es.
6. Once the rst lead wire has been secured with a cable e, begin wrap-
ping the wire around the pipe in any rotaon (clockwise or counter clock-
wise).
7. When nished wrapping the pipe secure the other lead wire with a cable
e as seen in diagram.
Screws and wall anchors
Single layer coil wrap
Double layer coil wrap