Technical data
– Operating Voltage: 10 15 V DC
– Power current: 60 mA
– Switching power: 5 A 250 V AC oder 5 A 30 V DC
– Wattage: max. 1000 W
– Measuring range: –55°C to +125,0°C
– Accuracy: (–55°C to –10°C): +/–2°C
(–10°C to +85°C): +/–0,5°C
(+85°C to +125°C): +/–2°C
– Resolution: 0,1°C
– Dimensions (L x B x H): 101 x 47 x 35 mm
– Cutout for front frame: 97 x 43 mm