Technical Specifications

H&C Products Group Technical Service 1.800.867.8246 Page 2 of 3
101 Prospect Avenue www.hcconcrete.com
Rev. 6/15
Cleveland, Ohio 44115 PDS ID: 70.000010
TOOLS REQUIRED
Natural bristle brush
Lamb’s wool or synthetic roller (3/8- to ½-inch nap)
Pump up sprayer (pressure 5 to 15 psi; tip Cone)
*Backrolling recommended after spraying
APPLICATION INSTRUCTIONS
Wait at least 24 hours after washing surface or after rain
before applying H&C® Natural Look Clear Sealer. Only apply
under dry conditions. Air and concrete surface temperatures
should be above 50°F and below 95°F for 24 hours following
application.
How to Apply: On horizontal surfaces, saturate in a single
application. Use enough material to keep the surface wet for
2-3 minutes before penetration. Broom or Back roll out any
puddles until excess material soaks into the surface. Dense
surfaces will only require a single application. Use enough to
completely wet the surface without creating drips, puddles or
rundown. Do not over apply. Test for application rate. On
vertical surfaces, apply the material from the bottom of the
wall upwards spraying so that it will run down the surface at
least six inches below the spray pattern. Typically, the surface
can be reopened to traffic in 1 hour and the surface should be
visibly dry.
Additional Coats: One coat of H&C® Natural Look Clear Sealer
is normally sufficient. Two coats may be required over bare
concrete for maximum protection. Allow a minimum of 4
hours dry time between coats. Apply second coat in a
perpendicular direction to the first coat.
SLIP RESISTANCE
Some surfaces such as inclined driveways, garages, steps, and
patios may require a slip-resistant additive for safety. If more
than two coats are applied, consider using a slip- resistant
additive in the final coat.
CLEANUP
Clean tools and any spills or spatters immediately using soap
and warm water.
MAINTENANCE
Clean light to moderately soiled surfaces with a 50/50
solution of a cleaner degreaser and water or with another
neutral-based cleaner, following the manufacturer’s
directions for use. Use the cleaner full strength for heavy
soiling, such as oil and grease stains.
PHYSICAL PROPERTIES
Physical Properties and Characteristics
Property
Test Method
Value
Dry Time (@ 77°F, 50% RH) Dry-to-touch 1 hour
Light foot traffic
2 hours
Heavy traffic
72-96 hours
Recoat 4 hours
VOC
EPA Method 24
<50 g/L
Finish
ASTM D523
Matte
QUV Weather Test ASTM-G151-97 1,000 hours, no effect
Chemical Resistance
(after one hour exposure/24
hrs recovery)
ASTM D1308
2% NaOH
No effect
5% Tide detergent
No effect
Gasoline Dulling
Brake fluid Dulling
Transmission fluid
No effect
Motor oil No effect
Volume Solids/ Weight Solids
ASTM D 5095
*Standard test method
used to determine
nonvolatile content in
reactive masonry
water repellants - this
test adds a catalyst to
the water repellant to
measure total solid.
After testing, total
solids for this product
is approximately 4%.
Active Content: 7%
*NOTE: Active content
is a calculated value
based on weight
percent of siloxane in
the total formulation.
Some active content
will be consumed upon
reaction with the
substrate.
Weight per Gallon ASTM D1475 8.26 lbs.
ORDERING INFORMATION
Clear Part Number
1 gallon 70.000010-16
5 gallon 70.000011-20
TECHNICAL SERVICES
The information and recommendations set forth in this product
data sheet are based on tests conducted by or on behalf of
H&C® Products Group and The Sherwin-Williams Company.
Such information and recommendations set forth herein are
subject to change and pertain to the product offered at the
time of publication. Consult your H&C® or Sherwin-Williams
representative to obtain the most recent product data sheet.
For technical assistance, call 1-800-867-8246 or visit
www.hcconcrete.com.