Operation Manual

11
M1 - T1 & M3 - T3 GYS AUTO
EN
CHOICE OF REELS
Possible settings :
type l
Torche 1
T1,T3,M1,M3
Torche 2
T3/M3
Spool gun
T1/T3/M1/M3
Gaz
acier
Ø 300 x
argon
+
CO2
Ø 200 x x
Ø 100 x
inox
Ø 200 x x
Ø 100 x
CuSi3 Ø 200 x x
argon
pur
CuAl8 Ø 200 x x
Alu
AlMg5
Ø 300 x*
Ø 200 x* x*
AlSi5 Ø 100 x
AlSi12 Ø 100 x
CuSi3: Recommandation OPEL & MERCEDES
CuAl8: Recommandation Peugeot/Citroën/Renault
AlSi12: Recommendation for automotive aluminium from metal sheet of 0,6mm to 1,5 mm of thickness.
* Consider Teon sheath and special aluminium contact tip
«MANUAL» MODE (FIG 5)
1-welding mode choice :
- Normal (2T) : standard two-stage welding
- Delay: intermittent welding modes for an optimised
operating procedure.
- Spot:spotwelding with ajustable spot diameter
2- Wire speed settings : wire speed tting potentiometer.
The speed varies from 1 to 15L/minute.
3- Spot/delay potentiometer tting
4- Manual mode : In manual mode, the wire speed is
determinated by the user by adjusting the potentiometer
(2).
5- Synergic mode: position the potentiometer (2) in the
middle of the «optimal synergic» zone. In this mode, the
device determines the optimal wire speed according to 3
parameters :
- Voltage
- Wire diameter
- The power mode.
It’s possible to adjust the wire speed +/-.
In position Normal(2T), 2 modes are proposed to ease
the settings of the device: Manual or Synergic.
6- thermal protection light : informs when a short break
is necessary following intensive use.
«MANUAL» MODE (FIG 5)
To set your device, proceed as follow:
- Choose the welding voltage using the 7 positions switch
Example: position 1 for 0,6mm metal sheets and position 7 for 4 mm metal sheets.
- Adjust the wire speed with the potentiometer(2).
Advice:
The wire speed adjustment is often determinated « with the noise »: the arc must be stable and have a low
crackling. If the speed is too low, the arc is not continuous. If the speed is too high, the arc crackles and the wire
pushes back the torch.