Operation Manual

19
EXAFEED 4L
EN
Save new settings :
- Hold buttons and during 3 seconds. appears, release the buttons.
- Turn one of the two knobs . Validate by pressing the button .
- The display indicates a memory set (01 to 50) while blinking.
- Turn the knob to select the memory set in which the desired settings will be saved. Validate by pressing the button
.
- The settings are saved / the menu exit is instantaneous.
Load existing settings :
- Hold buttons and during 3 seconds. appears, release the buttons.
- Turn one of the two knobs . Validate by pressing the button .
- The display indicates a memory set (01 to 50) while blinking.
- Turn one of the two knobs to select the memory slot containing the settings to load. Validate by pressing the button .
The settings are loaded / the menu exit is instantaneous.
Quick Load mode: Easy recall of saved welding parameters :
When the « Quick load » mode is active, the user can sequentially recall previously saved welding parameters, by briey pressing/releasing
the trigger. Slots 2 to 50 can store customisable welding parameters. (Example : Setting 5 will allow the user to recall, using he trigger, programs 01
to 05).
WELDING CYCLES
2T mode:
Burnback
Start
Hotstart
(1)
Welding Crater Filler
(2)
Voltage
Wire speed
Gas
Released
Held
Trigger
(1)
:
If the Hotstart phase feature is deactivated, the welding starts immeditately after the arc ignition (Start).
(2)
:
If the Crater Filler feature is deactivated, the wire is drawn back immediately after the trigger is released.