Manual
4
GC/G ARM RENOVATION KIT
PROCEDURE TO CHANGE THE QC BASE TO QC-G ON A GYSPOT BP-LQC
Warning ! The gyro is not com-
patible with the renove GC/G
kit at the risk of being blocked
by the QC arm.
The procedure for changing the QC to QC-G
arm base (064102) is linked to the procedure
for changing the QC to QC-G bracket on GYS-
POT BP.LQC (064096).
• From an arm of GYSPOT BP.LQC.
• Unscrew the two base xing screws.
> Do not reuse the 2 screws (M8x40) for xing the
new QC-G base.
• Remove the base from the arm
• If necessary, clean the surface of the arm in contact
with the base, with “ne grain” sandpaper.
Caution: Do not damage the contact surface
when cleaning.
• Apply copper grease or contact gel grease to the
contact surface of the arm.
• Place the QC-G base on the arm
• Block the base with the two screws provided in the
kit (M8x35 ref.42330). Place the Schnorr washers (M8
ref.41266) under the head.
• Tightening torque: 18Nm.