Manual
KIT RENOVATED GC/G CLAMP
EN
9
Gently remove the cover.
• Unscrew the screw coming from the push button of
side selection (1 M4x6 screw ref.41022).
• Disconnect the button connector
side selection button.
• Remove the shunt protection by pulling it towards
the back of the clamp.
• Disconnect the handle connector.
• Unscrew the screws of the power cable (2 screws
M8x30 CHC 42062 and 2 Schnorr washers M8 41266).
• Unscrew the 4 CHC M6x35 screws (42061) and 4
Schnorr M6 washers (41265) of the arm support.
Attention: You must keep the screws and
washers for the new support.