To perform a leak test:
1. Make 2~3 oz. of leak solution by mixing one part liquid dishwashing detergent and three parts water.
Noted: make sure control knob is “OFF”.
2. Apply several drops of solution where the cylinder attaches to regulator (See Figure 13), inspect the solution
at the connection looking for bubbles. If NO bubbles appear, the connection is secure. If bubbles appear, the
connection has the leak, disconnect the regulator, reconnect, perform another leak check. If you continue to
see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s supplier.
LIGHTING INSTRUCTIONS
1. Push in gas control knob slightly and turn to “OFF”.
2. Turn gas control knob the “ON/HI”.
3. Push in gas control knob all the way and hold. Continue to press the ignition button for 15 seconds.
4. If the burner does not light in 15 seconds, release the knob and it will pop back out. Wait 5 minutes before
attempting to light the burner again, repeat step 1 to 3.
1. Push in gas control knob
slightly and turn to “OFF”.
WARNING: For your safety, read and follow the Lighting Instructions in this manual and in the Rating Plate on
the appliance. IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD OR EXPLOSION
HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
TO TURN OFF GAS
12
LIGHTING INSTRUCTIONS:
1.Read instructions before lighting;
2.Push and turn the knob to LOW;
3.Hold ignitor to light the burner,
release control knob after 15 seconds;
if burner does not light, wait 5 minutes,repeat;
4.Adjust flame to desired flame with the control knob.
Figure 14
-
+