User manual
18
6-6. Remote Control
Short the Remote Control terminal for output ON, and open the Remote Control terminal for output OFF.
6-7. OVP Setting
Firstly, adjust the OVP ADJ knob clockwise to the maximum OVP, then adjust output voltage to reach the voltage of OVP.
Secondly, adjust the OVP ADJ knob counter-clockwise slowly until the OVP message appears. Then the setting value of
OVP is slightly less than the OVP which you intend to set.