User Manual

PSB-2000 Series User Manual
74
firmly.
NOTE
Approximately 1mA of current flows through the
sensing wires at the rated output voltage. Use
AWG 26 to 18 wires as the sensing wires.
Fig. Remote
Sensing
Connection
(PSB-L)
+S
+
-
-S
Load
OUTPUT
OUTPUT
Shielded cable or
Twisted pair wires
Fig. Remote
Sensing
Connection
(PSB-H)
+S
+
-
-S
Load
OUTPUT
OUTPUT
Shielded cable or
Twisted pair wires
+ -