User manual
GSP-9300 Programming Manual
92
:CALCulate:HARMonic:RESult?
Query
Description
Returns the amplitude of each harmonic in dBm.
Query Syntax
:CALCulate:HARMonic:RESult?
<fundamental>,<harmonic#2>,….<harmonic#n>
<fundamental>
Returns the amplitude of the
fundamental harmonic frequency in
dBm.
<harmonic#n>
Returns the amplitude of the nth
harmonic in dBm.
Query Example
:CALC:HARM:RES?
>-7.572e+01,0.00e+00,0.00e+00,0.00e+00,0.00e+00
:CALCulate:HARMonic:STATe
Set
Query
Description
Sets or queries the state of the Harmonics function.
Syntax
:CALCulate:HARMonic:STATe {ON|OFF}
Query Syntax
:CALCulate:HARMonic:STATe?
Parameter
OFF
Turn Harmonic measurement off.
ON
Turn Harmonic measurement on.
Return parameter
0
Harmonic measurement is off.
1
Harmonic measurement is on.
Example
:CALC:HARM:STAT ON
:CALCulate:JITTer:STATe
Set
Query
Description
Sets or queries the state of the Jitter Analysis
function.
Syntax
:CALCulate:JITTer:STATe {ON|OFF|1|0}
Query Syntax
:CALCulate:JITTer:STATe?