User manual
REMOTE CONTROL
115
OFF
Turns pass/fail limit off.
ON
Turns pass/fail limit on.
Return parameter
0
Turns pass/fail limit off.
1
Turns pass/fail limit on.
Example
:CALC:TOI:LIM:STAT ON
:CALCulate:TOI:RESult?
Query
Description
Returns the third order intercept and the pass/fail
judgments.
Query syntax
:CALCulate:TOI:RESult?
Return parameter
<3
rd
lower>
3
rd
order lower intercept
<lower p/f>
3
rd
order lower pass/fail judgment.
0=pass, 1=fail
<3
rd
upper>
3
rd
order upper intercept
<upper p/f>
3
rd
order lower pass/fail judgment
0=pass, 1=fail
Example
:CALC:TOI:RES?
>-5.5e+1,0, -6.61e+1,0
:CALCulate:TOI:STATe
Set
Query
Description
Turns TOI measurement on/off or queries its state.
Syntax
:CALCulate:TOI:STATe {ON|OFF|1|0}
Query Syntax
:CALCulate:TOI:STATe?
Parameter
0
Turns TOI measurement off.
1
Turns TOI measurement on.
OFF
Turns TOI measurement off.
ON
Turns TOI measurement on.
Return parameter
0
TOI measurement is off.
1
TOI measurement is on.
Example
:CALC:TOI:STAT ON