User manual
GSP-9300 Programming Manual
176
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?
Query
Description
Returns the start frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.
Query syntax
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?
Parameter/
Return parameter
<n>
Offset 1 to 5
<NR3>
Start frequency in Hz
Example
:SEM:OFFS1:ADD:FREQ:STAR?
>2.5e+6
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?
Query
Description
Returns the stop frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.
Query syntax
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?
Parameter/
Return parameter
<n>
Offset 1 to 5
<NR3>
Stop frequency in Hz
Example
:SEM:OFFS1:ADD:FREQ:STOP?
>3.5e+6