User manual
GSP-9300 Programming Manual
120
:DISPlay:DEMod[:WINDow]:TRACe:X
[:SCALe]:RPOSition
Set
Query
Description
Sets or queries the Reference Position of the trace
for AM/FM demodulation (x-axis grid division).
Syntax
:DISPlay:DEMod[:WINDow]:TRACe:X[:SCALe]:
RPOSition <integer>
Query Syntax
:DISPlay:DEMod[:WINDow]:TRACe:X[:SCALe]:
RPOSition?
Parameter/
Return parameter
<integer>
<NR1>1~10
Example
:DISP:DEM:TRAC:X:RPOS 2
:DISPlay:DEMod[:WINDow]:TRACe:X
[:SCALe]:RVALue
Set
Query
Description
Sets or queries the Reference value time.
Syntax
:DISPlay:DEMod[:WINDow]:TRACe:X[:SCALe]: RVALue
<time>
Query Syntax
:DISPlay:DEMod[:WINDow]:TRACe:X[:SCALe]:
RVALue?
Parameter
<time>
<NRf>
Return parameter
<NR3>
Seconds
Example
:DISP:DEM:TRAC:X:RVAL 2 ms
:DISPlay:DEMod[:WINDow]:TRACe:Y
[:SCALe]:AUTO
Set
Description
Sets the vertical display scale to auto for AM/FM
demodulation.
Syntax
:DISPlay:DEMod[:WINDow]:TRACe:Y[:SCALe]:AUTO
Example
:DISP:DEM:TRAC:Y:AUTO