User manual

REMOTE CONTROL
103
Return parameter
<NR3>
Peak threshold. Note: the unit returned
depends on the currently set vertical
units.
Example
:CALC:MARK:PEAK:THR -3 dBm
:CALCulate:MARKer:PEAK:THReshold:
STATe
Set
Query
Description
Sets or queries the state of the Peak Threshold.
Syntax
:CALCulate:MARKer:PEAK:THReshold:STATe
{ON|OFF|1|0}
Query Syntax
:CALCulate:MARKer:PEAK:THReshold:STATe?
Parameter
0
Turn peak threshold off.
1
Turn peak threshold on.
OFF
Turn peak threshold off.
ON
Turn peak threshold on.
Return parameter
0
Peak threshold is off.
1
Peak threshold is on.
Example
:CALC:MARK:PEAK:THR:STAT ON
:CALCulate:MARKer<n>:SET
Set
Description
Sets the selected marker to one of five preset
positions.
Query Syntax
:CALCulate:MARKer<n>:SET {CENTer|STARt|STOP
|STEP|RLEVel}
Parameter
<n>
<NR1> Marker number 1~6
CENTer
Set to center frequency
STARt
Set to start frequency
STOP
Set to stop frequency
STEP
Set to CF STEP frequency
RLEVel
Set to the Reference level
Example
:CALC:MARK1:SET CENT