User manual
GSP-9300 Programming Manual
100
:CALCulate:MARKer<n>:NOISe:Y?
Set
Query
Description
Returns the normalized noise level over a BW of
1Hz from the marker position.
Query Syntax
:CALCulate:MARKer<n>:NOISe:Y?
Parameter
<n>
<NR1> Maker number 1~6.
Return parameter
<NR3>
Normalized noise level in the Y-axis unit.
Example
:CALC:MARK1:NOIS:Y?
>1.166e+2
:CALCulate:MARKer<n>:PEAK
Set
Description
Sets the selected marker to the selected peak.
Query Syntax
:CALCulate:MARKer<n>:PEAK {MAXimum|
MINimum|NEXT|RIGHt|LEFT}
Parameter
<n>
<NR1> Marker number 1~6
MAXimum
Highest peak value
MIMimum
Lowest peak value
NEXT
Next peak
RIGHt
Next peak right
LEFT
Next peak left
Example
:CALC:MARK1:PEAK NEXT
:CALCulate:MARKer:PEAK:CTRack:STATe
Set
Query
Description
Sets or queries the state of the Peak Track function.
The Peak Track function only applies to the
currently selected marker.
Syntax
:CALCulate:MARKer:PEAK:CTRack:STATe
{ON|OFF|1|0}
Query Syntax
:CALCulate:MARKer:PEAK:CTRack:STATe?