User Manual
REMOTE CONTROL
67
Query Example
GSB1:CHAN?
> 12345678<cr><lf>
>GSB-01:HXXHXXXX<cr><lf>
>GSB-02:XLXXXLXX<cr><lf>
>GSB-XX:XXXHXXXX<cr><lf>
>GSB-XX:XXXHXXXX<cr><lf>
Indicates that for MANU 001, channel 1 and 4 are set
to H for the GSB-01 and that channel 2 and 6 are set
to L for the GSB-02.
GSB:MEASure
Query
Description
Returns the test results for the scanner boxes after
the test has completed.
Note
Only applicable in the VIEW or READY status.
Pass/Fail results we be held until the “GSB:CLR”
command is used or the results will be overwritten
each time a new test is performed.
Query Syntax
GSB:MEASure?
Return parameter
<string>
Returns the test pass/fail results in a
table as follows:
12345678<cr><lf>
GSB-01:PXXPXXXX<cr><lf>
GSB-02:XFXXXFXX<cr><lf>
GSB-XX:XXXXXXXX<cr><lf>
GSB-XX:XXXXXXXX<cr><lf>
Where the first line is the channel
index and lines 2~5 are the test result
for the scanner boxes in order from
1
st
to 4
th
.
P=Pass
F=Fail
X=Test off