User manual

Table Of Contents
REMOTE CONTROL
141
MANU:UTILity:ARCMode
Set
Query
Sets or returns the ARC mode status for the
current test.
The ARC mode cannot be set for the IR and GB
function.
MANU:UTILity:ARCMode {OFF|ON_CONT|
ON_STOP}
MANU:UTILity:ARCMode?
OFF
Turns ARC mode off.
ON_CONT
Sets ARC mode to ON and
CONTINUE.
ON_STOP
Sets ARC mode to ON and STOP.
MANU:UTIL:ARCM OFF
Turns ARC mode OFF.
MANU:UTILity:PASShold
Set
Query
Sets or returns the PASS HOLD setting for the
current test.
MANU:UTILity:PASShold {ON|OFF}
MANU:UTILity:PASShold?
OFF
Turns PASS HOLD off.
ON
Turns PASS HOLD on.
MANU:UTIL:PASS OFF
Turns PASS HOLD OFF.
MANU:UTILity:FAILmode
Set
Query
Sets or returns the FAIL mode setting for the
current test.
MANU:UTILity:FAILmode {CONT|HOLD|STOP}
MANU:UTILity:FAILmode?