User Manual
    GPT-9000/9000A Series User Manual 
170 
ARC DETECT 
Yes 
Rise-time Control Function 
Yes 
RAMP (Ramp Time) 
0.1~999.9S 
TIMER (Test Time) 
OFF
2
, 0.5S~999.9S 
GND 
ON/OFF 
1
 At least 0 .5 seconds is needed to reach a set voltage of 50V/2mA. 
2
 The timer can only be turned off under special MANU mode (MANU=***-000). 
Insulation Resistance Test 
Output Voltage 
50V~1000V *GPT-99XX/99XXA also includes a 
125V test point. 
Output Voltage Resolution 
50V 
Output Voltage Accuracy 
(1% of setting+5V) with no load 
Resistance Measurement 
Range 
1M~ 9500M (GPT-98XX) 
1M~ 50G (GPT-99XX/99XXA) 
Test Voltage 
Measurement Range 
Accuracy 
(GPT-98XX) 
50V≤V≤450V 
1~50MΩ 
±(5% of reading +1 count) 
51~2000MΩ 
±(10% of reading +1 count) 
500V≤V≤1000V 
1~500MΩ 
±(5% of reading +1 count) 
501~9500MΩ 
±(10% of reading +1 count) 
(GPT-99XX/ 99XXA) 
50V≤V≤450V 
0.001~0.050GΩ 
±(5% of reading +1 count) 
0.051~2.000GΩ 
±(10% of reading +1 count) 
500V≤V≤1000V 
0.001~0.500GΩ 
±(5% of reading +1 count) 
0.501~9.999GΩ 
±(10% of reading +1 count) 
10.00~50.00GΩ 
±(20% of reading +1 count) 
Output Impedance 
600kΩ 
Window Comparator Method 
Yes 
Rise-time Control Function 
Yes 
RAMP (Ramp Time) 
0.1~999.9S 
TIMER (Test Time) 
1S~999.9S 
GND 
OFF 