User Manual
    GPT-9000/9000A Series User Manual 
152 
Parameter/ 
Return parameter 
<NR1> 
Description 
0 
Turn all lines off/all lines are off. 
1 
Displays the graph line for the primary 
test item. See page 77 for details. 
For example: V for ACW, DCW and IR 
tests, I for GB tests. 
2 
Displays the graph line for the secondary 
test items. 
For example: I for ACW and DCW tests, 
R for IR and GB tests. 
3 
Turn all lines on/all lines are on. 
Example 
SWEEP:GRAP:LINE 3 
Turns all the graph lines on. 
SWEEP:STARt:TIME 
Set
Query
Description 
Sets or returns the start time (STA.t) of the sweep 
graph in milliseconds. 
This setting will also set what the time will be for 
the first point for the sweep data that is returned in 
the SWEEP:DATA:SHOW query. 
Syntax 
Query Syntax 
SWEEP:STARt:TIME <NR2> 
SWEEP:STARt:TIME ? 
Parameter/ 
Return parameter 
<NR2> 
0.1~1999.8 seconds 
Example 
SWEEP:STARt:TIME 1000.0 
Sets the sweep start time to 1000 seconds. 