Instructions
COMMAND OVERVIEW
205
Note
When output items are deleted, subsequent items
shift forward to fill the empty positions.
Empty positions at the end are set to NONE.
If the second <NRf> is omitted, only the output
item specified by the first number is deleted.
:NUMeric[:NORMal]:HEADer
Description
Returns the numeric data header.
Syntax
:NUMeric[:NORMal]:HEADer? {<NRf>}
Parameter
<NRf>
1 to 50 (item number)
Example
• If <NRf> is specified, only the data name for the
specified item number is output.
:NUMERIC:NORMAL:HEADER? 1
-> U-E1
• If <NRf> is omitted, the data names of the items
from 1 to the number specified by the :
NUMeric[:NORMal]:NUMber command are output in
order.
:NUMERIC:NORMAL:NUMBER 3
:NUMERIC:NORMAL:HEADER?
-> U-E1,I-E1,P-E1
:NUMeric:LIST
Description
Returns all harmonic measurement numeric list
data output settings.
Query Syntax
:NUMeric:LIST?
Return parameter
<String>
Note
The number of numeric list data items output by :
NUMeric:LIST:ITEM<x> is determined by :
NUMeric:LIST:NUMber.
Query
Query