Instructions

COMMAND OVERVIEW
171
<Boolean>0
<Boolean>1
OFF
ON
0
1
Turn the harmionic display off.
Turn the harmionic display on.
: HARMONICS:DISPLAY:STATE OFF
: HARMONICS:DISPLAY:STATE?
->:HARMONICS:DISPLAY:STATE 0
:HARMonics:DISPlay:ORDer
Sets or returns the harmonic order of the harmonic
component that is shown in graph->hormoics->bar
page for the harmonic measurement data display.
:HARMonics:DISPlay:ORDer {<NR1>}
:HARMonics:DISPlay:ORDer?
<NR1>
1 to 50 (harmonic order).
:HARMONICS:DISPLAY:ORDER 1
:HARMONICS:DISPLAY:ORDER?
->:HARMONICS:DISPLAY:ORDER 1
:HARMonics:PLLSource
Sets or returns the PLL source.
:HARMonics:PLLSource {U1|I1}
:HARMonics:PLLSource?
U1
Select pll source at voltage.
I1
Select pll source at current.
:HARMONICS:PLLSOURCE U1
:HARMONICS:PLLSOURCE?
->:HARMONICS:PLLSOURCE U1
Set
Query
Set
Query