Datasheet

GPE-X323 Specifications
The specifications apply when the GPE-X323 is powered on for at least 30 minutes under +20°C~+30°C.
GPE-4323
GPE-3323
GPE-2323
GPE-1326
Output Mode
Number of Channel
CH1
CH2
CH4
CH1
CH2
CH3
CH1
CH2
CH1
Voltage
0~32V
0~32V
0~15V
0~32V
0~32V
5.0V
0~32V
0~32V
0~32V
Current
0~3A
0~3A
0~1A
0~3A
0~3A
5A
0~3A
0~3A
0~6A
Tracking Series Voltage
0~64V
----
0~64V
----
0~64V
----
Tracking Parallel Current
0~6A
0~6A
0~6A
Constant Voltage Operation
Line Regulation
0.01%+3mV
Load Regulation
0.01%+3mV(rating current 3A)
0.02%+5mV(rating current 3A)
Ripple & Noise
1mVrms(5Hz~1MHz)
Recovery Time
100μs(50% Load Change, minimum load 0.5A)
Constant Current Operation
Line Regulation
0.2%+3mA
Load Regulation
0.2%+3mA
Ripple & Noise
3mArms
Tracking Operation(CH1,CH2)
Tracking Error
0.1%+10mV of Master(0~32V) No Load , with Load add load regulation100mV)
Parallel Regulation
Line: 0.01%+3mV
Load:0.01%+3mV(rating current3A)
0.02%+5mV(rating current3A)
Series Regulation
Line: 0.01%+5mV
Ripple & Noise
Load:100mV
CH3 Operation for (GPE-3323)
Output Voltage
5.0V, ±5%
Output Current
5A
Line Regulation
3mV
Load Regulation
5mV
Ripple & Noise
1mVrms(5Hz~1MHz)
Meter
Voltage Resolution
100mV(*1)
Current Resolution
10mA(*1)
Setting Accuracy
Voltage±(0.1% of reading +30mV)
Current±(0.3% of reading +6mA)
Readback Accuracy
Voltage±(0.1% of reading +30mV)
Current±(0.3% of reading +6mA)
Insulation
Chassis and Terminal
20MΩ or above (DC 500V)
Chassis and AC Cord
30MΩ or above (DC 500V)
Environment Condition
Operation Temp
0~40
Storage Temp
-10~70
Operating Humidity
80% RH
Storage Humidity
70% RH
Other
Power Source
AC100V/120V/220V±10%; 230V(+10%~-6%); 50/60Hz
Dimensions & Weight
210(W)x 155(H) x 306(D) mm ; Approx. 7kg

Summary of content (2 pages)