User manual
REMOTE CONTROL
39
Command List
• Detailed descriptions of each command start from the next page.
• The “HELP” command shows all the below commands and their
meanings, except for the HELP command itself.
ISET<X>:<NR2>
Sets the output current.
ISET<X>?
Returns the output current setting.
VSET<X>:<NR2>
Sets the output voltage.
VSET<X>?
Returns the output voltage setting.
IOUT<X>?
Returns the actual output current.
VOUT<X>?
Returns the actual output voltage.
TRACK<NR1>
Selects the operation mode.
BEEP<BOOLEAN>
Turn on or off the beep.
OUT<BOOLEAN>
Turn on or off the output.
STATUS?
Returns the GPS-3303D or GPS-3303S status.
*IDN?
Returns the GPS-3303D or GPD-3303S
identification.
RCL<NR1>
Recalls a panel setting.
SAV<NR1>
Saves the panel setting.
HELP?
Shows the command list.
ERR?
Returns the instrument error messages.
GPD-3303 Series User Manual
40
Command Details
ISET<X>:<NR2>
Description
Sets the output current.
Panel operation
See page23
Response time
Minimum 70ms
Example ISET1:2.234
ISET1:2.23
Sets the CH1 output current to
2.234A (for GPD-3303S)
Sets the CH1 output current to
2.23A (for GPD-3303D)
ISET<X>?
Description
Returns the output current setting.
Panel operation
See page23
Response time
Minimum 80ms
Example ISET1?
Returns the CH1 output current setting
VSET<X>:<NR2>
Description
Sets the output voltage.
Panel operation
See page23
Response time
Minimum 70ms
Example VSET1:20.345
VSET1:20.3
Sets the CH1 voltage to 20.345V
(for GPD-3303S)
Sets the CH1 voltage to 20.3V
(for GPD-3303D)