User manual

OPERATION
33
3. To turn on the output, press
the output key. The key
LED turns on.
4. The CH2 indicator turns
red, indicating tracking
parallel (PARA) mode.
5. Press the CH1 key (LED
turns on) and then use the
Voltage and Current knob
to set the output voltage
and current. The CH2
output control is disabled.
By default, the Voltage and
Current knob work in the
coarse mode. To activate the
fine mode, press the knob to
turn the FINE LED on.
(Fine control)
6. For the output level and CV/CC status, refer to
the CH1 meter and indicator.
Voltage level
The CH1 meter reading shows
the output voltage. In the above
case, 20.0V.
Current level
Double the amount of CH1
current meter reading. In the
above case, 2.0A x 2 = 4.0A.
GPD-3303 Series User Manual
34
SAVE/RECALL SETUP
Save Setup
Background
The front panel settings can be stored into one of
the four internal memories.
Contents
The following list shows the setup contents.
Independent / tracking series / tracking parallel
mode
CH1/CH2 knob selection
Fine/coarse editing mode
Output voltage/current level
The following settings are always saved as “off”.
Output on/off
Front panel lock/unlock
Panel operation
Press one of the 1~4 Memory
keys for 2 seconds, for example
memory 1. The panel settings
are saved in memory 1 and the
key LED turns on. When the
panel settings are modified, the
LED turns off.
Note
When a setting is stored, the output automatically
turns off.