202
Auto counter 6 digits, range from 2Hz minimum to the rated
bandwidth
Power
Measurements
(Option)
Power Quality
Measurements
VRMS, V Crest Factor, Frequency, IRMS, I Crest
Factor, True
Power, Apparent Power, Reactive Power, Power
Factor, Phase Angle.
Harmonics Freq, Mag, Mag rms, Phase, THD-F, THD-R, RMS
Ripple
Measurements
V, I
In-rush current
First peak, second peak
Control Panel
Function
Autoset Single-button, automatic setup of all channels for
vertical, horizontal and trigger systems, with undo
autoset
Auto-Range allow users to quickly move from test point to test
point without having to reset the oscilloscope for
each test point
Save Setup 20set
Save
Waveform
24set
Display TFT LCD Type 8" TFT LCD SVGA color display
Display
Resolution
800 horizontal × 600 vertical pixels (SVGA)
Interpolation Sin(x)/x & Equivalent Time Sampling
Waveform
Display
Dots, vectors, variable persistence, infinite
persistence
Display
Graticule
8 x 10 divisions
Display
Brightness
Adjustable
Interface RS232C DB-9 male connector
USB Port 2 sets USB 2.0 High-speed host port ;1 set USB
High-speed 2.0 device port
Ethernet Port RJ-45 connector, 10/100Mbps
SVGA Video
Port
DB-15 female connector, monitor output for
display on SVGA monitors
GPIB USB-to-GPIB converter (Option)
Go-NoGo
BNC
5V Max/10mA TTL Open collector output
Internal flash
disk
64MB
Kensington
Style Lock
Rear-panel security slot connects to standard
Kensington-style lock.
Line output Go/NoGo audio alarm
Trigger out
BNC
5V TTL output