User manual
Table Of Contents
- SAFETY INSTRUCTIONS
- GETTING STARTED
- QUICK REFERENCE
- Menu Tree / Operation Shortcuts
- Convention
- Acquire Key
- Acquire Key - Segments
- Autoset Key
- CH1 ~ 4 Key
- Cursor Key
- Display Key
- Help Key
- Math Key
- Measure Key
- Hardcopy Key
- Run/Stop Key
- REF Key
- Save/Recall Key
- Test Key
- Test Key – Go-NoGo
- Trigger Type Menu
- Trigger Edge Menu
- Trigger Delay Menu
- Trigger Pulse Width Menu
- Trigger Video Menu
- Trigger Pulse Runt Menu
- Trigger Rise & Fall Menu
- Trigger Timeout Menu
- Utility Key
- Utility Key – I/O
- Utility Key – File Utilities
- Utility Key – Wave Generator - Demo Outputs
- Search - Edge
- Search – Pulse Width
- Search - Runt
- Search – Rise/Fall Time
- Zoom Key
- Option Key
- Default Settings
- Built-in Help
- Menu Tree / Operation Shortcuts
- MEASUREMENT
- CONFIGURATION
- OPTIONAL SOFTWARE and APPS.
- SAVE/RECALL
- FILE UTILITIES
- HARDCOPY KEY
- REMOTE CONTROL CONFIG
- MAINTENANCE
- FAQ
- I connected the signal but it does not appear on the display.
- I want to remove the (Measurement result / FFT result / Help contents) from the display.
- The waveform does not update (frozen).
- The probe waveform is distorted.
- Autoset does not catch the signal well.
- I can’t save files to the internal memory.
- The display image printout is too dark on the background.
- The date and time settings are not correct.
- The accuracy does not match the specification.
- APPENDIX
- INDEX
APPENDIX
251
Coupling
AC,DC,LF rej. ,Hf rej. ,Noise rej.
Sensitivity
DC ~ 100MHz Approx. 1div or 1.0mV
100MHz ~ 200MHz Approx. 1.5div or 15mV
200MHz ~ 300MHz Approx. 2div or 20mV
External
Trigger
Range
±15V
Sensitivity
DC ~ 100MHz Approx. 100mV
100MHz ~ 200MHz Approx. 150mV
200MHz ~ 300MHz Approx. 150mV
Input
Impedance
1MΩ// 16pF
Horizontal
Time base
Range
1ns/div ~ 100s/div (1-2-5 increments)
ROLL: 100ms/div ~ 100s/div
Pre-trigger
10 div maximum
Post-trigger
1000 div maximum.
Accuracy
±20 ppm over any ≥ 1 ms time interval
Real Time
Sample Rate
1CH: 2GSa/s; 2CH: 1GSa/s
ET Sample
Rate
100GSa/s maximum for all models
Record Length
1CH: 2Mpts; 2CH: 1Mpts
Acquisition
Mode
Normal, Average, Peak Detect, Single
Peak
Detection
2nS (typical)
Average
selectable from 2 to 256
X-Y Mode
X-Axis Input
Channel 1; Channel 3*
*four channel models only
Y-Axis Input
Channel 2; Channel 4*
*four channel models only
Phase Shift
±3° at 100kHz
Cursors and
Measurement
Cursors
Amplitude, Time, Gating available
Automatic
Measurement
36 sets: Pk-Pk, Max, Min, Amplitude, High, Low,
Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle
Area, ROVShoot, FOVShoot, RPREShoot,
FPREShoot, Frequency, Period, RiseTime, FallTime,
+Width, -Width, Duty Cycle, +Pulses, -Pulses,
+Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR,
LFF, Phase
Cursors
measurement
Voltage difference between cursors ( ∆V) Time
difference between cursors ( ∆T)
Auto counter
6 digits, range from 2Hz minimum to the rated
bandwidth
Control Panel
Function
Autoset
Single-button, automatic setup of all channels for
vertical, horizontal and trigger systems, with undo
Autoset