Datasheet
Standard Demo Procedure of Segmented Memory Function
Equipments:
1. GDS-2000A Digital Storage Oscilloscope + Logic Analyzer
Selected Module * 1
2. GDB-03 Demo Board *1
3. Digital Probe *1
Steps/ Procedures:
1. Connect the digital probes with GDB-03 Demo Board via the
connection port of Logic Analyzer on GDS-2000A.
。
2. Adjust the function adjusting knob of GDB-03 demo board to “SPI”
function selection. Press the “Option” Key at the bottom-right hand side
of the screen to turn on the Logic Analyzer, then turn on the 0-7 channel
display.
The connect point on
GDB-03